P91 Online UPS – Scalable Runtime Rack/Tower UPS (1000–3000VA, 120V)

1000–3000 VA | 120V | Online Double-Conversion UPS

Runtime-flexible online UPS engineered for distributed IT, AV, retail, and multi-site infrastructure requiring continuous power conditioning and scalable runtime.

Product Number
90000621: P91C-1000 LD 1U 120VAC 1000VA/800W
MSRP: $1170 (each)

90000756: P91-1000 LD 2U 120VAC 1000VA/1000W
MSRP: $1220 (each)

90000622: P91-1500 LD 2U 120VAC 1500VA/1450W
MSRP: $1595 (each)

90000623: P91-2000 LD 2U 120VAC 2000VA/1930W
MSRP: $2080 (each)

90000624: P91-3000 LD 2U 120VAC 3000VA/2880W
MSRP: $2770 (each)

 

P91 Model Guide 
MODELCAPACITYFORM FACTORRECEPTACLESDIMENSIONS (WxDxH)WEIGHTINTERNAL BATTERY
P91c-10001000 VA / 800 W1U(3) NEMA 5-15R17.2 x 17.8 x 1.7 in28 lb(4) 6V 290 W
P91-10001000 VA / 1000 W2U(8) NEMA 5-15R17.2 x 15.1 x 3.5 in25.5 lb(2) 12V 9Ah
P91-15001500 VA / 1450 W2U(8) NEMA 5-15/20R17.2 x 15.1 x 3.5 in34.2 lb(3) 12V 9Ah
P91-20002000 VA / 1930 W2U(1) NEMA 5-15R17.2 x 19 x 3.5 in43 lb(4) 12V 9Ah
P91-30003000 VA / 2880 W2U(1) L5-30R + (6) 5-15/20R17.2 x 23.8 x 3.5 in60.6 lb(6) 12V 9Ah

 

SKU: 90000621, 90000756, 90000622, 90000623, 90000624 Category: Brand:

Airflow Management Awareness Month

Our 6th annual Airflow Management Awareness Month webinar series has concluded. Watch the webinars on-demand now!

  • Online Double-Conversion Topology: Continuously conditions incoming AC power with zero millisecond transfer time to battery during power outages.
  • Highly Scalable External Battery Pack Architecture: Supports adding up to seven matching external battery packs (BP36, BP48, or BP72) with an adjustable charger (up to 8 A) that recharges systems to 95% in under 3 hours.
  • Near-Unity Output Power Factor (2U Models): Delivers higher active power output (e.g., up to 1450 W on a 1500 VA unit and 2880 W on a 3000 VA unit).
  • Shallow-Depth 2U/1U Convertible Form Factor: Compact physical depth (starting at 15.1 inches) with included brackets for rack or tower installation, plus wall-mount options.
  • Serviceability & Auto-Restart Capabilities: Supports an optional maintenance bypass module (XBDM) and features automatic restart when utility power returns after a full battery discharge.
  • Uninterrupted, High-Quality Power Protection: Isolates critical network, AV, and IT equipment from sags, spikes, noise, and frequency variations, preventing hardware damage and data loss.
  • Customizable & Extended Back-up Runtimes: Allows organizations to engineer specific runtime goals per site—scaling from a few minutes of ride-through up to two hours—without overpaying for larger, fixed-runtime UPS units.
  • Maximum Usable Capacity Per Rack: Provides more real wattage per VA than competing units, allowing you to power higher-density equipment loads without stepping up to a larger frame size.
  • Fits Tight Equipment Racks & Closets: The shallow chassis depth fits easily into short-depth racks and crowded IT spaces while leaving room for cable management.
  • Minimized Downtime & Reduced Site Visits: The optional maintenance bypass lets technicians swap or service the UPS without dropping connected loads, while auto-restart automatically recovers systems after prolonged outages without requiring an on-site technician.