P91g Li Lithium Rack UPS – Online Double-Conversion (1500–3000 VA, 208–240V)

1500–3000 VA | 208–240 V | Online Double Conversion

Lithium rack UPS with online double-conversion topology for distributed IT, network closet, AV, and edge infrastructure. LiFePO₄ batteries deliver long lifecycle performance and high-temperature operation up to 50 °C.

Product Number
90000753: P91G-1.5KLI 2U 230VAC 1500VA/1350W
MSRP: $2700 (each)

90000754: P91G-2KLI 2U 230VAC 2000VA/1800W
MSRP: $3980 (each)

90000755: P91G-3KLI 2U 230VAC 3000VA/2700W
MSRP: $4900 (each)

 

P91g LI Model Guide 
MODELCAPACITYRECEPTACLESINLET/CORDDIMENSIONS (WxDxH)WEIGHTBATTERY CONFIG
P91g-1.5kLi1500 VA / 1350 W(8) IEC C13C14 inlet · L6-20P, 8 ft17.2 x 15.1 x 3.5 in25.6 lb15S2P
P91g-2kLi2000 VA / 1800 W(8) IEC C13C14 inlet · L6-20P, 8 ft17.2 x 19 x 3.5 in33.5 lb15S2P x2
P91g-3kLi3000 VA / 2700 W(1) IEC C19 + (8) C13C20 inlet · L6-20P, 8 ft17.2 x 23.8 x 3.5 in45.2 lb24S1P x3
SKU: 90000753, 90000754, 90000755 Category: Brand:

Airflow Management Awareness Month

Our 6th annual Airflow Management Awareness Month webinar series has concluded. Watch the webinars on-demand now!

  • LiFePO₄ Battery Chemistry with Dual Redundant BMS: Engineered with high-durability lithium iron phosphate cells that provide up to a 15-year service life (3,000–5,000 discharge cycles) and protected by dual redundant Battery Management Systems for cell balancing and overload control.
  • 208–240V Online Double-Conversion Topology: Designed for higher-voltage global operations, continuously regenerating AC power with pure sine wave output and zero transfer time during outage events.
  • 50°C (122°F) High-Temperature Rating: Formally rated to operate safely in harsh ambient environments up to 50°C.
  • Flexible 2U Convertible Design with IEC Outlets: Versatile 2U chassis with international IEC C13/C19 receptacles that can be mounted as a rack, tower, or wall-mounted.
  • Fast 1.5-Hour Recharge & Easy-Replace Internal Pack: Features LCD-adjustable charging (up to 8 A) that recovers batteries to 90% capacity in approximately 1.5 hours, alongside hot-serviceable battery access and optional XBDM bypass compatibility.
  • Substantially Lower Total Cost of Ownership (TCO): Operating up to four times longer than standard VRLA lead-acid UPS units, the 15-year battery life eliminates routine replacement cycles and field service visits across global multi-site infrastructure.
  • Total Power Conditioning for High-Voltage Equipment: Complete isolation from voltage sags, spikes, noise, and frequency fluctuations protects sensitive 208–240V IT, AV, and telecom hardware with zero power gap.
  • Uncompromising Reliability in Non-Conditioned Spaces: Provides dependable backup performance in hot, uncooled network closets, industrial enclosures, and telecom nodes without suffering the rapid battery degradation typical of lead-acid units.
  • Fast Outage Recovery & Zero-Downtime Maintenance: Rapid 1.5-hour recharge ensures quick system recovery between power drops, while the easy-replace battery pack and maintenance bypass options allow technicians to swap batteries without dropping critical loads.
  • Standardized Global Deployment: TAA compliance combined with global 208–240V IEC support allows enterprise IT teams to deploy a single, consistent, low-maintenance UPS platform across international locations.