P91 5–10kVA Online UPS – 208–240V Rack UPS with Scalable Runtime

5–10 kVA | 208–240 VAC | Online Double Conversion

Centralized rack UPS platform engineered for distributed infrastructure requiring scalable runtime, integrated bypass capability, and predictable performance across IT, telecom, and industrial environments.

Product Number
90000640: P91-5K SCLRUN 2U 208–240V 5KVA/5KW
MSRP: $2541 (each)

90000641: P91-6K SCLRUN 2U 208–240V 6KVA/6KW
MSRP: $2970 (each)

90000642: P91-10K SCLRUN 2U 208–240V 6KVA/6KW
MSRP: $4158 (each)

 

Three Models, 5-10kVA
MODELCAPACITYDIMENSIONS (WxDxH)WEIGHTEFFICIENCY
P91-5K5 kVA / 5 kW17.2 x 23.6 x 3.5 in33.1 lbUp to 94% online / 99% ECO
P91-6K6 kVA / 6 kW17.2 x 23.6 x 3.5 in33.1 lbUp to 94% online / 99% ECO
P91-10K10 kVA / 10 kW17.2 x 23.6 x 3.5 in39.7 lbUp to 94% online / 99% ECO
SKU: 90000640, 90000641, 90000642 Category: Brand:

Airflow Management Awareness Month

Our 6th annual Airflow Management Awareness Month webinar series has concluded. Watch the webinars on-demand now!

  • Unity Power Factor (PF 1.0): Delivers full real-power output (kW = kVA across 5 kVA, 6 kVA, and 10 kVA models), ensuring maximum usable power without capacity derating.
  • Scalable External Battery Module Architecture: Built around hot-swappable external VRLA battery cabinets (BPXR2U240A / BPXR3U240A) that scale system runtime from minutes to multiple hours.
  • Online Double-Conversion Topology: Continuously conditions incoming AC power, delivering zero millisecond transfer time to battery and maintaining less than 4% total harmonic distortion (THD).
  • Integrated Maintenance Bypass & Distribution (Optional XBDM): Supports an optional XBDM module featuring a manual maintenance bypass switch and individually breakered output receptacles.
  • Optional Step-Down Isolation Transformer (240/120V): Compatible with an optional step-down transformer (e.g., XPD-IT60A) to provide galvanically isolated 120V and split-phase 240/120V outputs for mixed-voltage loads.
  • Maximum Usable Capacity per Rack Unit: Unity power factor supplies up to 10% more real wattage than standard 0.9 PF competitors (e.g., a full 5 kW on a 5 kVA unit), allowing you to power denser IT, industrial, and telecom loads in the same footprint.
  • Tailored Backup Runtimes for Extended Outages: External battery scaling allows organizations to engineer backup duration specifically to site needs—bridging long-duration outages or generator startup delays without being bound by fixed internal battery limits.
  • Complete Isolation & Protection for Sensitive Infrastructure: Isolates critical enterprise racks, broadcast media systems, and automation gear from grid disturbances, voltage sags, spikes, and frequency fluctuations without power gaps.
  • Zero-Downtime System Serviceability: The optional maintenance bypass switch allows IT staff to service, repair, or replace the main UPS module without cutting power to connected downstream equipment.
  • Simplified Multi-Voltage Power Distribution: The optional step-down transformer allows high-capacity 208–240V power to safely supply standard 120V IT, AV, or laboratory devices without requiring separate standalone low-voltage UPS systems..

Pin It on Pinterest